Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. What could be the problem with a system please help. E-102: Communication error between indoor unit and outdoor unit. Riavvio Automatico > In caso di interruzione dell’alimentazione elettrica, le unità, al ripristino procedono a … FAQ su Samsung Climatizzatori. Does it stop because it is the completion time? -Current sensor error. Check again at the cooling / heating state. Maggiori informazioni su 'Cos'è l'errore "E161" su Multi Split (FJM) del condizionatore Samsung?' Primi di luglio 20climatizzatore con garanzia scaduta (ha anni) accendo, errore sul … Indoor unit can not receive any data from outdoor unit. Is the battery inserted in the wrong way(+, -)? Raise the desired temperature than the current one? These cookies do not store any personal information. Displayed in indoor unit. © 2014-2020 ACErrorCode.com. Your email address will not be published. Tipo di lavoro: Riparazione o manutenzione condizionatore. Funzioni Come si usa la modalità Good Sleep del climatizzatore? Prohibit starting during operation of the Crack case heater, Error due to repeated communication address, Error on room temperature sensor of indoor unit (Short or Open), Error on EVA IN sensor of indoor unit (Short or Open), Error on EVA OUT sensor of indoor unit (Short or Open), Communication error sends from indoor unit, Indoor unit EEV open failure(When 2* detection), Indoor unit EEV close failure(When 2“ detection), Indoor unit floating S/V error(When 2“ detection), Error on thermal fuse of indoor unit (Open), Communication error between indoor unit and outdoor unit (Pre tracking failure or when actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power supply (The error occurs with the failure regardless of the number of devices), Communication error between indoor and outdoor unit (When not received in every room after completing the tracking), Communication error between outdoor unit inv - main micom (For PF #4~#6 controller, error will be determined from the time when compressor turns on), Error on outdoor temperature sensor (Short or Open), Error on outdoor COND OUT sensor (Short or Open), Digital comp.1 discharge temperature sensor(Short or Open), Fixed comp.1 discharge temperature sensor(Short or Open), Fixed comp.2 discharge temperature sensor(Short or Open), Fixed comp.3 discharge temperature sensor(Short or Open), Fixed compl Discharge temperature sensor breakaway, Fixed comp2 Discharge temperature sensor breakaway, Fixed comp3 Discharge temperature sensor breakaway, Digital compl Sump temperature sensor breakaway. Does it interfered with the radio of neon sign? Ho un urgente bisogno del codice di reset per il mio climatizzatore Samsung modello AQV12AWAN . Unità Interne Polivalenti Mono-Multi > Le unità interne della gamma SIRIUS possono essere usate in configurazione Mono con le relative unità esterne o anche quali terminali per le unità Multi (SIRIUS 9, 12, 18 IU). What should I do? of installation for indoor unit/ventilation system (ERV) (16 equipment devices), - Mixed installation error for°C/°F indoor unit, Only detected by the master wired remote control, -Wired remote control °C/°F setting error. Called the person who installed it and he tells me he will come and look at . Domande frequenti (FAQ) per elettrodomestici Samsung… I have a error code E500 contact failure on IPM of inverter PBA1 Since the temperature is automatically set, the temperature setting is not required. … E-211: When single indoor unit uses 2 MCU ports that are not in series. Can be connected by both master and slave wired remote controls. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed. Required fields are marked *. - Exceeded maximum no. Is the filter clogged with dust or dirty? C ontactez le service client Samsung … Soluzioni e Suggerimenti, Scarica il Manuale, Contattaci. Were you able to get this resolved? How do I fix an error E654 on my Samsung split AC? nel Supporto Samsung. Fixed compl Sump temperature sensor breakaway, Fixed comp2 Sump temperature sensor breakaway, Fixed comp3 Sump temperature sensor breakaway, Comp.1 Sump temperature sensor(Short or Open), Compressor down due to freeze protection control, System stop due to overload protection control, Comp, down by the sump protection control, Comp, down by the discharge temperature sensor, Heating operation restricted at outdoor temperature over TheatJiigh value (default: 30 °C), Cooling operation restricted at outdoor temperature below Tcooljow value (default 0°Q, Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C, Start prohibition by refrigerant pressure error, Error due to operation failure of inverter compressor, System stop due to OLP temperature control, Error due to abnormal rotation of the compressor or unconnected wire of compressor, Error on DC-Link voltage sensor (Short or Open), Outdoor unit EEPROM Read/Write error (Option), Outdoor unit EEPROM Read/Write error (H/W), Error on IPM Heat Sink sensor of inverter 1 (Short or Open), Error on input current sensor of inverter 1 (Short or Open), Error due to mismatching capacity of indoor and outdoor unit, Switch option setting error(rvot applied), Indoor unit floating S/V error(When 1“ detection), Indoor unit EEV close failure(When 1“ detection), Indoor unit EEV open failure(When 1“ detection), Communication cables of indoor and outdoor units, Wired remote controller communication error, Wired remote controller cables, Wired remote controller, Communication error between indoor unit and outdoor unit, Communication error between wired remote controller and indoor unit, Operation LED and reservation LED flickering (1Hz period), Operation LED and filter LED flickering (1 Hz period), Reservation LED filter LED alternating flickering (1Hz period), Reservation LED and filter LED flickering (1Hz period), Indoor and outdoor communication abnormal, Operation LED and reservation LED alternating flickering (1Hz period), Wired remote controller communication abnormal, Check of departure of indoor temperature sensor, Check of indoor exchanger sensor departure, Check of outdoor exchanger sensor departure, When the electrical heater is over heated, Check of heater temperature sensor departure, Error of temperature sensor in the indoor unit (Open/5hort), Error of setting option switches for optional accessories, Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data, Communication Error between Outdoor Main and Inverter Micom, (Occurred after 1 minute detection in Main and Inverter), Indoor Unit Eva in Sensor (Open/Short Error), Outdoor Temp Sensor Error (Open/Short Error), CONDTemp. You also have the option to opt-out of these cookies. Tipo di impianto: Pompa di calore. The temperature setting is not required since the wind volume set automatically. Is the selected temperature too high? E-108: Error due to repeated address setting, E-121: Error on indoor temperature sensor of indoor unit, E-122: Error on EVA IN sensor of indoor unit, E-123: Error on EVA OUT sensor of indoor unit, E-128: EVA IN temperature sensor of indoor unit is detached from EVA IN pipe, E-129: EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe, E-130: Heat exchanger in/out sensors of indoor unit are detached, E-135: RPM feedback error of indoor unit’s cleaning fan. The standard temperature ±2˚C during the automatic operation. Richieste relative a Riparazione o manutenzione condizionatore; Errore e4 climatizzatore samsung digital inverter wifi; Errore e4 climatizzatore samsung digital inverter wifi. Is the selected temperature too low? Le bouton Power reste enfoncé en permanence. Ricerca guasti DAIKIN – VERIFICHE ED OPERAZIONI DEVONO ESSERE ESEGUITE DA TECNICI QUALIFICATPECIALIZZATI. Hi Julie, I have code E559 and my indoor unit. Scopri di più su Guida rapida alle promozioni Samsung nella pagina di Supporto Samsung. That has been 3 months ago. Lower the selected temperature lower than the current one (during cooling). This website uses cookies to improve your experience while you navigate through the website. further, the repair man has been to my aircon so many times in an attempt to fix it his comment on the last call was “I feel like part of the family” on the last 2 occasion he found Samsung cant even send the right parts to fix it. any ideas what i have to check? -Heatsink sensor error. Grazie a tutti. Samsung Split Type, Multi System and VRF System AC Error Codes and Troubleshooting; Outdoor LED Display Error and Check Method (12K/18K/24K)-Samsung Split System Air Conditioning Outdoor LED Light Errors, Explanation: Communication error (unable to receive data), Main checking Point/Remark: Communication cable connection, Explanation: Communication error (outdoor cannot communicate), Main checking Point/Remark: Another indoor unit or indoor PCB, Explanation: Indoor unit room temperature sensor error (Open/Short), Main checking Point/Remark: Room temperature sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger in sensor, indoor PCB, Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger out sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor detached, Main checking Point/Remark: Heat exchanger in sensor, Explanation: Indoor unit heat exchanger out temperature sensor detached, Main checking Point/Remark: Heat exchanger out sensor, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point/Remark: Heat exchanger in & out sensor, Explanation: Indoor unit fan motor malfunction, Main checking Point/Remark: Fan motor and cable, Explanation: More than 2 indoor units cool and heat simultaneously, Main checking Point/Remark: Another indoor unit operation mode, Main checking Point/Remark: Cable connection (Indoor & Outdoor unit), Explanation: The number of indoor unit mismatched, Main checking Point/Remark: Cable connection (another indoor unit & outdoor unit), SW01(outdoor), Explanation: Compressor discharge sensor error(Short/Open), Main checking Point/Remark:  Outdoor unit, Main checking Point/Remark: Outdoor unit (Error code).