This website uses cookies to ensure you get the best experience Our, https://www.samsung.com/levant/air-conditioners, Actron AC Error Codes and Troubleshooting, Hitachi AC Error Codes and Troubleshooting, Godrej AC Error Codes and Troubleshooting, INDOOR MID, INDOOR IN PIPE-TH sensor error, DIS-TH(Discharge Temperature) Sensor Error, Prohibit Operation Condition Error (Heating), Prohibit Operation Condition Error (Cooling), Indoor unit room temperature sensor error (open / short), Indoor unit heat exchanger temperature sensor error (open / short), Lamp flickering-Lamp flickering-Lamp flickering, Lamp off -Lamp flickering-Lamp flickering, Abnormal communication error (Indoor - Outdoor unit), Lamp flickering-Lamp off -Lamp flickering, Outdoor unit temperature sensor error; Outdoor temp.-sensor, Deice temp.-sensor, OLP temp.-sensor, Discharge temp.-sensor, Heatsink temp.-sensor. This error occurs when the option settings of the master and slave wired remote controls are different from each other. Tipo di lavoro: Riparazione o manutenzione condizionatore. Check again at the state of Cooling / Fan only / Heating. how do I repair. Grazie a tutti. Who can help me ? Sensor Error (Open/Short Error), Inverter Compressor Discharge Temp, sensor Error (Open/Short Error), Outdoor unit - indoor unit communication wire miss connection, Outdoor unit refrigerant Full leakage {Gas leak), (Inverter) Heatsink temperature over Error, Communication error between Indoor unit and wired remote control, Communication error between Master and Slave wired remote control, Error of setting option for wired remote control COM2, Communication error between wired remote control < -> indoor unit/ventilation system (ERV) (When communication has stopped for 3 minutes after detecting indoor unit/ventilation system (ERV) and wired remote control), Tracking 10 or more errors between wired remote control < -> indoor unit/ventilation system (ERV). Ogni giorno il sito viene aggiornato con nuovi manuali uso. E-101: Indoor unit communication error. E-108: Error due to repeated address setting, E-121: Error on indoor temperature sensor of indoor unit, E-122: Error on EVA IN sensor of indoor unit, E-123: Error on EVA OUT sensor of indoor unit, E-128: EVA IN temperature sensor of indoor unit is detached from EVA IN pipe, E-129: EVA OUT temperature sensor of indoor unit is detached from EVA OUT pipe, E-130: Heat exchanger in/out sensors of indoor unit are detached, E-135: RPM feedback error of indoor unit’s cleaning fan. Essendo suddetto … Ricerca guasti DAIKIN – VERIFICHE ED OPERAZIONI DEVONO ESSERE ESEGUITE DA TECNICI QUALIFICATPECIALIZZATI. Riavvio Automatico > In caso di interruzione dell’alimentazione elettrica, le unità, al ripristino procedono a … Samsung Supporto IT C ontactez le service client Samsung . C ontactez le service client Samsung . Joseph, Your email address will not be published. Is the selected temperature too low? Can be connected by both master and slave wired remote controls. Your email address will not be published. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed. Is the detection part of the indoor unit blocked? Domande frequenti (FAQ) per elettrodomestici Samsung… i have a samsung inverter a/c model adv18ugan , when i suitch on from main, i have red light on ,after about a minute i have red lighton,green light on and yellow light blinking. Tipo di impianto: Pompa di calore. - Exceeded maximum no. | View our. bE1 ou bC1 . Richieste relative a Riparazione o manutenzione condizionatore; Errore e4 climatizzatore samsung digital inverter wifi; Errore e4 climatizzatore samsung digital inverter wifi. and the list goes on and on and on they even promised to replace it but that never eventuated…, its e203 communication error…lose or bad wire between indoor and outdoor unit. Samsung Split Type, Multi System and VRF System AC Error Codes and Troubleshooting; Outdoor LED Display Error and Check Method (12K/18K/24K)-Samsung Split System Air Conditioning Outdoor LED Light Errors, Explanation: Communication error (unable to receive data), Main checking Point/Remark: Communication cable connection, Explanation: Communication error (outdoor cannot communicate), Main checking Point/Remark: Another indoor unit or indoor PCB, Explanation: Indoor unit room temperature sensor error (Open/Short), Main checking Point/Remark: Room temperature sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger in sensor, indoor PCB, Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger out sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor detached, Main checking Point/Remark: Heat exchanger in sensor, Explanation: Indoor unit heat exchanger out temperature sensor detached, Main checking Point/Remark: Heat exchanger out sensor, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point/Remark: Heat exchanger in & out sensor, Explanation: Indoor unit fan motor malfunction, Main checking Point/Remark: Fan motor and cable, Explanation: More than 2 indoor units cool and heat simultaneously, Main checking Point/Remark: Another indoor unit operation mode, Main checking Point/Remark: Cable connection (Indoor & Outdoor unit), Explanation: The number of indoor unit mismatched, Main checking Point/Remark: Cable connection (another indoor unit & outdoor unit), SW01(outdoor), Explanation: Compressor discharge sensor error(Short/Open), Main checking Point/Remark:  Outdoor unit, Main checking Point/Remark: Outdoor unit (Error code). The standard temperature ±2˚C during the automatic operation. Samsung Supporto IT Gino 10 Giugno 2019. Necessary cookies are absolutely essential for the website to function properly. (during heating). Soluzioni e Suggerimenti, Scarica il Manuale, Contattaci. You also have the option to opt-out of these cookies. E-212: If the rotary switch (on the MCU) for address setting of the indoor unit has 3 or more of the same address, E-213: When total number of indoor units assigned to MCU is same as actual number of installed indoor units but there is indoor unit that is not installed even though it is assigned on MCU, E-214: When number of MCU is not set correctly on the outdoor unit or when two or more MCU was installed some of them have the same address, E-215: When two different MCU’s have same address value on the rotary switch. Since the temperature is automatically set, the temperature setting is not required. My aircon display lights starts blinking and out comes warm air. Mauro. E-151: Error due to opened EEV of indoor unit (2nd detection), E-152: Error due to closed EEV of indoor unit (2nd detection), E-153: Error on floating switch of indoor unit (2nd detection), E-161: Mixed operation mode error of indoor unit; When outdoor unit is getting ready to operate in cooling. C ontactez le service client Samsung … Non riesco a trovarlo su nessun sito. Codici errori climatizzatori samsung- Ricerca Tecniche per il controllo dell affidabilità dei caratteri (parità) o dei blocchi dei dati. Il s'agit d'une panne technique. Indoor unit is not installed in case of outside gearing (when the indoor unit is not detected after outside gearing option setting and tracking are finished). and Samsung make the worst air conditioners on the market. I have error code E320 can you please help. The error indicated on the LED display of Indoor unit; Outdoor Unit Error mode and check method; Explanation: Communication error (indoor unable to receive data), Main checking Point: Communication cable connection, Explanation: Communication error (outdoor unable to communicate), Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Explanation: Indoor unit sensor error – Evaporator pipe in sensor detached, Explanation: Indoor unit sensor error – Evaporator pipe out sensor detached, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point: Indoor unit operation mode, Explanation: The number of indoor unit mismatched, Main checking Point: Communication wiring, Explanation: Communication error (outdoor unable to receive data), Explanation: Communication error between 2 microcontroller on the outdoor PCB, Explanation: Condenser temperature sensor error (Short/Open), Explanation: Condenser temperature sensor detached, Explanation: Compressor discharge sensor error (Short/Open), Explanation: Compressor discharge sensor detached, Explanation: Compressor OLP sensor error (Short/Open), Explanation: Indoor unit heat exchanger freezing and compressor stop (cooling mode), Main checking Point: Check pipe matching also (indoor-outdoor), Explanation: Outdoor unit overload and compressor stop (protection control in heating mode), Explanation: Outdoor unit high discharge temperature and compressor stop, Main checking Point: Check pipe matching (indoor-outdoor), Explanation: Outdoor unit EEV open error (self diagnosis), Explanation: Outdoor unit EEV close error (self diagnosis), Explanation: High temperature (over 30˚C) of outdoor as heating mode, Explanation: Low temperature (under -5˚C) of indoor as cooling mode, Explanation: Wrong connection between communication and power cable, Main checking Point: Wiring indoor and outdoor, Explanation: Inverter Compressor starting failure (5 times), Main checking Point: Service valve, EEV, Compressor terminal, Compressor wire, Outdoor controller, Explanation: Compressor trip by input current limit control, Main checking Point: EEV, Gas over charge, Outdoor controller, Explanation: Compressor trip by OLP temperature limit control, Main checking Point: Outdoor fan, Compressor,  Outdoor controller, Explanation:  Compressor peak current protection, Main checking Point:  Outdoor fan, Compressor, Compressor wire, Outdoor controller, Explanation: Compressor overload protection by current, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: DC-link voltage error (under 150V or over 410V), Main checking Point: Power voltage, Outdoor controller, Main checking Point: Compressor terminal, Compressor wire, Outdoor controller, Explanation:  DC-link voltage sensor error, Explanation: Compressor overload protection, Main checking Point: Outdoor fan, EEV, Service valve, Outdoor controller, Explanation: AC line zero-crossing detection circuit error, Main checking Point: Outdoor controller, Terminal Block, Explanation: NO GAS error (self diagnosis), Samsung VRF (DVM S) System AC Error Codes. E-149: Error due to AHU master indoor unit sensor setting. This category only includes cookies that ensures basic functionalities and security features of the website. Un bouton autre que le bouton Power reste enfoncé en permanence. Comment:*document.getElementById("comment").setAttribute( "id", "ade8436854dfd09f261f79fdbb4a5313" );document.getElementById("g2bf16c3b0").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. Soluzioni e Suggerimenti, Scarica il Manuale, Contattaci. What could be the problem with a system please help. AR12HSFNCWKN. Is the selected temperature too high? Called the person who installed it and he tells me he will come and look at . I have a problem in Samsung inverter split a.c unit.indoor unit show error E109.What its means and what should I do.please help. E-216: When indoor unit is not installed to a MCU port but the switch on the port is set to On. and fortunately for lots of potential purchasers I have convinced them to choose anything rather than Samsung. Condizionatore Samsung errore E4: cosa significa. 29/07/2017 0 risposte Napoli ID richiesta: 142797. Hi Julie, Le bilance hanno funzionato perfettamente dal 2007 e solo ora hanno iniziato a mostrare il peso … Indoor unit can not receive any data from outdoor unit. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Error code related to the Communications / Settings / HW (cont. AR18HSFNBWKN. I have a error code E500 contact failure on IPM of inverter PBA1 That has been 3 months ago. Fixed compl Sump temperature sensor breakaway, Fixed comp2 Sump temperature sensor breakaway, Fixed comp3 Sump temperature sensor breakaway, Comp.1 Sump temperature sensor(Short or Open), Compressor down due to freeze protection control, System stop due to overload protection control, Comp, down by the sump protection control, Comp, down by the discharge temperature sensor, Heating operation restricted at outdoor temperature over TheatJiigh value (default: 30 °C), Cooling operation restricted at outdoor temperature below Tcooljow value (default 0°Q, Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C, Start prohibition by refrigerant pressure error, Error due to operation failure of inverter compressor, System stop due to OLP temperature control, Error due to abnormal rotation of the compressor or unconnected wire of compressor, Error on DC-Link voltage sensor (Short or Open), Outdoor unit EEPROM Read/Write error (Option), Outdoor unit EEPROM Read/Write error (H/W), Error on IPM Heat Sink sensor of inverter 1 (Short or Open), Error on input current sensor of inverter 1 (Short or Open), Error due to mismatching capacity of indoor and outdoor unit, Switch option setting error(rvot applied), Indoor unit floating S/V error(When 1“ detection), Indoor unit EEV close failure(When 1“ detection), Indoor unit EEV open failure(When 1“ detection), Communication cables of indoor and outdoor units, Wired remote controller communication error, Wired remote controller cables, Wired remote controller, Communication error between indoor unit and outdoor unit, Communication error between wired remote controller and indoor unit, Operation LED and reservation LED flickering (1Hz period), Operation LED and filter LED flickering (1 Hz period), Reservation LED filter LED alternating flickering (1Hz period), Reservation LED and filter LED flickering (1Hz period), Indoor and outdoor communication abnormal, Operation LED and reservation LED alternating flickering (1Hz period), Wired remote controller communication abnormal, Check of departure of indoor temperature sensor, Check of indoor exchanger sensor departure, Check of outdoor exchanger sensor departure, When the electrical heater is over heated, Check of heater temperature sensor departure, Error of temperature sensor in the indoor unit (Open/5hort), Error of setting option switches for optional accessories, Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data, Communication Error between Outdoor Main and Inverter Micom, (Occurred after 1 minute detection in Main and Inverter), Indoor Unit Eva in Sensor (Open/Short Error), Outdoor Temp Sensor Error (Open/Short Error), CONDTemp.